SERVICING THE SCOREBOARDWhile your scoreboard was designed for years of trouble-free operation, some problems may occasionally occur. Electro-Mech Scoreboard Company offers onsite service in some areas. In other areas, we can help you contact an independent service technician. In areas in which service is not available from Electro-Mech Scoreboard Company, we will make every effort to answer your questions. Our trained personnel at Electro-Mech Scoreboard Company are ready to answer your questions from Monday to Friday during the hours of 8 AM to 5 PM Eastern Standard Time. Be sure to know your scoreboard model number when calling. Scoreboard replacement parts are always available. Damaged parts can usually be repaired at a significant cost savings. Our convenient toll free number is listed at the bottom of every page in this manual. COMPONENT REPLACEMENTLED Digits And Indicators Replacement The LEDs that form digits and indicators are soldered on circuit boards mounted behind metal masks. Do not attempt to replace individual LEDs. In case of a malfunction, the entire LED circuit board must be removed. To avoid damage to the LED driver module, always turn off the power to the scoreboard when removing or replacing LED digits and indicators. Figure 6 shows the components of a LED digit assembly. LED indicator assemblies are similar in construction.
Horn Replacement All other components are located behind the PERIOD panel of each cabinet. Figure 7 shows the view behind the PERIOD panel.
LDM1 LED DRIVER MODULE FUNCTIONS
LED Driver Module Replacement Electrical connections to the LDM1 LED DRIVER MODULE are made with ribbon cable polarized IDC sockets and locking ramp crimp terminal housings that mate with jacks on the module. The module is secured inside the scoreboard with four machine screws.
To avoid damage to the module, always turn off the power to the scoreboard when removing or replacing it. LPS-130VA LED POWER SUPPLY MODULE FUNCTIONS
Figure 8 shows the location of the LPS-130VA Power Supply Module fuses. The tables below figure 8 list their functions.
LPS-130VA FUSES
Note: Other manufacturer’s fuses may be substituted for the Bussmann fuses. LED Power Supply Module Replacement Electrical connections to the LED POWER SUPPLY MODULE LPS-130VA are made with three keyed plugs that mate with jacks on the left side of the module. The module is secured inside the scoreboard with two machine screws.
To avoid damage to the module, always turn off the power to the scoreboard when removing or replacing it.
|