LOCKER ROOM CLOCK OPERATION
LOCKER ROOM CLOCK STARTUP
- Place the circuit breaker for the locker room clock in the ON position.
- Plug one end of the extension cable into the ¼”stereo jack on the junction box or the ScoreLink 200 Transmitter, if purchased.
- Plug the other end into the ¼”stereo jack mounted on the control console back plate.
- Plug the control console power cord into a grounded NEMA 5-15R 120 VAC receptacle.
- If a ScoreLink 200 RF MODEM SYSTEM is installed with this locker room clock, plug the wall mount DC power supply into a grounded NEMA 5-15R 120 VAC receptacle and the male plug on the end of the attached cable into the Power jack on the Transmitter.
GAME TIME OPERATION
This locker room clock is operated with a 37-key control console. Figure 4 shows the keypad layout on the control console.

Figure 4 Keypad Layout
Immediately after the control console power cord is plugged into a 120 VAC source, the console LCD display will read:
|
ELECTRO-MECH 2.6
SCOREBOARD MPBWV
|
After a few seconds the display will read:
|
000 D15:00 0 000
00 00 0 00
|
The locker room clock will display 15:00.
Control Console Key Functions
- Press [SET CLOCK]. The console LCD display will read:
|
000 D15:00 0 000
SET CLK <00:00>
|
Press the keypad numbers for the time, [ENTER]. Example: Press [SET CLOCK], [6], [0], [0], [0], [ENTER] on the control console. 60:00 will be displayed on the clock section of the scoreboard.
- Press [SET CLOCK .1 SEC]. The console LCD display will read:
|
000 D15:00 0 000
SET SEC <00.0>
|
Press the keypad numbers for the time, [ENTER]. Example: Press [SET CLOCK .1 SEC], [5], [3], [8], [ENTER] on the control console. 53.8 will be displayed on the clock section of the scoreboard.
- To turn this function off, press [.1 SEC ON/OFF]. The console LCD display will read:
|
CLOCK ON <1>
.1 SEC OFF <0>
|
Press [0], [ENTER] on the control console.
- To make the clock count up, press [CLOCK UP / DOWN]. The console LCD display will read:
|
GAME UP <1>
CLOCK DOWN <0>
|
Press [1], [ENTER] on the control console. The letter D in front of the game time on the console LCD will be replaced with the letter U to indicate that the clock is in the count up mode. To reset the clock to count down mode, press [CLOCK UP / DOWN], [0], [ENTER] on the control console.
- THE GAME CLOCK WILL BE INOPERABLE UNTIL THE TIME OF DAY FUNCTION IS TURNED OFF. To turn the time of day clock on, press [TIME OF DAY]. The console LCD display will read:
|
TIME OF ON <1>
DAY CLOCK OFF<0>
|
Press [1], [ENTER] on the control console. The console LCD display will then read:
|
00 C12:00 0 00
SET CLK <12:00>
|
Press the keypad numbers for the time, [ENTER]. The letter C will be displayed on the console LCD display to the left of the time to indicate that the time of day function is active. The scoreboard will display the time of day.
- CLOCK ON/OFF – This key is used to start and stop the clock.
- To reset the scoreboard, press [NEW GAME]. The console LCD display will read:
Press [1], [ENTER] on the control console. The scoreboard will reset its functions.
|
RESET YES<1>
SCOREBOARD NO<0>
|
- CLEAR – This key clears the information being entered into the control console.
The other keys are not used with the model 2106 locker room clock, but may be used for a compatible basketball scoreboard.
LOCKER ROOM CLOCK SHUTDOWN
- Place the power disconnect for the locker room clock in the OFF position.
- Unplug the control console power cord.
- Unplug the extension cable.
- If a ScoreLink 200 RF MODEM SYSTEM is installed with this locker room clock, unplug the Transmitter’s wall mount power supply.
- These units are not waterproof.
Proper locker room clock shutdown will help protect the locker room clock and control console from power surges and lightning strikes.