SERVICING THE SOFTBALL TIMERWhile your softball timer was designed for years of trouble-free operation, some problems may occasionally occur. Electro-Mech Scoreboard Company offers onsite service in some areas. In other areas, we can help you contact an independent service technician. In areas in which service is not available from Electro-Mech Scoreboard Company, we will make every effort to answer your questions. Our trained personnel at Electro-Mech Scoreboard Company are ready to answer your questions from Monday to Friday during the hours of 8 AM to 5 PM Eastern Standard Time. Be sure to know your softball timer model number when calling. Softball timer replacement parts are always available. Damaged parts can usually be repaired at a significant cost savings. Our convenient toll free number is listed at the bottom of every page in this manual.
If the softball timer turns on LEDs, but does not operate normally, make note of which functions are affected. If some LEDs either never turn on or always stay on, make note of their specific locations on the softball timer. Refer to the COMPONENT REPLACEMENT section of this manual before changing parts.
COMPONENT REPLACEMENTLED digits are serviced from the front of the softball timer.
LED Digits Replacement
The LEDs that form digits and indicators are soldered on circuit boards mounted behind the scoreboard face. Do not attempt to replace individual LEDs. In case of a malfunction, the entire LED circuit board must be removed. To avoid damage to the LED driver module, always turn off the power to the softball timer when removing or replacing LED digits. Figure 12 shows the components of a LED digit assembly. LED indicator assemblies are similar in construction.
![]() Figure 12 LED Digit Assembly
![]() Figure 13 LED Digit Ribbon Cable Connection Diagram All other components are located behind the access panel. Figure 14 shows the view behind the access panel.
![]() Figure 14 Access Panel Components LX14 LED DRIVER BOARD FUNCTIONS
LX14 Driver Board Replacement
Electrical connections to the LX14 LED DRIVER BOARD are made with ribbon cable polarized IDC sockets and locking ramp crimp terminal housings that mate with jacks on the circuit board. The circuit board is secured inside the softball timer on a metal bracket with two hex nuts.
To avoid damage to the circuit board, always turn off the power to the softball timer when removing or replacing it.
LPS5 LED POWER SUPPLY MODULE FUNCTIONS
Figure 15 shows the location of the fuses in the LPS5 LED Power Supply Module. The table following the figure lists the fuse ratings, functions, and part numbers.
![]() Figure 15 LPS5 Fuse Locations LPS5 FUSES
Note: Other manufacturer’s fuses may be substituted for the Bussmann fuses.
LED Power Supply Module Replacement
Electrical connections to the LED POWER SUPPLY MODULE LPS5 are made with four keyed plugs that mate with jacks on the left side of the module. The module is secured inside the softball timer with four machine screws.
To avoid damage to the module, always turn off the power to the softball timer when removing or replacing it.
|